Product Details:
|
Product Name: | R48-4000e | Maximum Current: | 24.7 A |
---|---|---|---|
Maximum Power: | 4000 W @ Vout >48 VDC | Dimensions (H X W X D): | 132 X 85.3 X 287 Mm / 5.2 X 3.36 X 11.3 Inches |
Weight: | 3.5 Kg / 7.7 Ibs | Voltage: | -42 VDC To -58 VDC |
Power Factor: | 0.99 | Warranty: | 1 Year |
High Light: | 4000W Rectifier Modules,48V Rectifier Modules,R48 4000e |
R48 4000e 48V 4000W Rectifier Modules Communication Power Module
Verity Emerson Communication Power Module R48-4000e 48V 4000W High Efficiency Rectifier Module
Description
The eSure R48-4000e high-efficiency rectifier is designed to convert standard AC supply voltages into stable nominal 48 VDC voltage that is adjustable to application needs. The R48-4000e is a constant power rectifier designed with the latest patented switchmode technology, using DSP (Digital Signal Processor) functionality for efficient operation.
For a higher load capacity, rectifiers can be connected in parallel, and intelligent control can be added with the help of a separate controller.
Features and Benefits
* Optimized depth-reduced footprint allows installation in short-depth racks and cabinets.
* DSP (Digital Signaling Processor)- means fewer components, optimized operation and active load sharing for increased reliability.
* High efficiency, 95.5%-reduces power consumption for lower operating costs.
* Hot pluggable-facilitates future extensions.
* Wide input voltage range-operates in the most demanding environments where input voltage changes.
* Wide temperature operating range (-40°C / -40 °F to +75°C / 167°F) -meets the harshest climatic environment requirements.
Specifications
Voltage |
85 VAC to 305 VAC (see figure 1) 200 VAC to 277 VAC (nominal) |
Frequency | 45 Hz to 65 Hz |
Maximum Current | 24.7 A |
Power Factor | 0.99 |
Voltage | -42 VDC to -58 VDC |
Maximum Power | 4000 W @ Vout >48 VDC |
Maximum Current | 83 A @ -48 VDC, limit set point 8.3 A to 83 A (see figure 2) |
Peak Efficiency | 95.8% |
Psophometric Noise (System) | <2 mV ; <32 dBrnc |
Alarms and Signaling | Alarm and status reported via CAN bus to system controller |
Visual Indications |
Green LED: Power On Yellow LED: Protection Red LED: Alarm Flashing Red LED: Fan Failure |
Operating Temperature | -40°C to +75°C / -40°F to +167°F (see figure 3) |
Storage Temperature | -40°C to +70°C / -40°F to +158°F |
Relative Humidity | 0 to 95% |
Altitude | 2000 m / 6560 ft at full power |
Safety | EN 60950-1, IEC 60950, UL 60950 |
EMC | ETSI EN300 386: 2005, FCC CFR 47 Part 15,Telcordia GR-1089-CORE issue 6 (Class B conducted and radiated) |
Environment | FEE,CE,CCC |
Dimensions (H x W x D) | 132 x 85.3 x 287 mm / 5.2 x 3.36 x 11.3 inches |
Weight | 3.5 kg / 7.7 Ibs |
1R484000E | eSure™ rectifier, 48 VDC, 4000 W |